• Contact Us
English (US)
ES Spanish
GR Greek
PL Polish
DE German
US English (US)
PT Portuguese
NL Dutch
FR French
RU Russian
IT Italian
  • Home
  • MEET
  • Monitors

970089 WIT A10/A Monitor Installer Manual

Written by Tecnico Internacional

Updated at January 19th, 2026

  • MEET
    Monitors Shared functions MEET monitors Panels Shared functions MEET panels Guard Unit Others
  • DUOX
    Monitors
+ More

Description 

The following document is the Installation Manual for the FERMAX MEET range monitors, corresponding to WIT A10/A monitor V03.70.

The monitor includes the Android 10 operating system and allows the installation of third-party applications. Fermax is not responsible for any incompatibilities with the hardware or operating system if the installer has installed an application that requires additional components, more powerful hardware or a version higher than Android 10. Likewise, even if the application works initially, future updates may no longer be compatible for the same reasons.

Installation

Stand placement

 
 

Attaching the monitor to the stand 

 
 

Configuring diagram

The MEET monitor is connected to the installation by means of connectors: ethernet for LAN connection and MOLEX type connectors for other connections (power supply, RS-485 and sensor inputs).

A bag containing the corresponding male plugs with their cables is enclosed with the monitor´s connector

  • MEET Static IP: Ethernet connector to the building's LAN installation. PoE for WIT monitors. 
  •  APRTMENT Dynamic IP: Ethernet connector to the home’s local LAN installation. Only WIT 10” monitor. 
  • +12V:  12 Vdc power input for non-PoE installations.
  • Siren / Sensors:
    • S: 12 Vdc auxiliary output synchronised with the activation of any sensor.          
      The maximum current is 100 mA.
    • -: GND.
    • Z1-Z7: sensor inputs. Z8 is reserved for tamper.
  • 12V +,-,485+,485-: Power output and RS-485 connection for the 10 Relay Module Ref. 1616. 

NOTE:
APRTMENT Dynamic IP connection requires a DHCP server, as it is not possible to assign an IP address from the monitor.

 
 

Wired alarm and doorbell sensors

 
 

Wiring of FERMAX MEET Relay Module Ref. 1616

 
 

Local programming from the monitor

Installer access

 
 

Basic configuration of the monitor

 
 

Configuring the alarm settings

 
 

Enable/disable functions

 
 

Enable/disable function icons on the monitor

If a third-party application (APP) has been installed, 

Touch the icon to enable a previously installed APP according to the procedure indicated in section Installation of third-party applications.           

 
 

Change installer pin

 
 

Web browser programming

Device

 
 

General

 
 

Network configuration

 
 

IP Camera

 
 

SIP

 
 

Advanced

The MEET monitors allow you to divert your calls to other devices such as:

  • Other MEET monitors in the installation
  • SIP devices
  • Mobile phones (via MEET-ME APP)
  • SIP EXT.: Use this drop-down to set up call forwarding from this monitor to other devices (NONE, 1, 2, 3 or 4). The form will be automatically adapted depending on the number chosen.     
    Indicate the URL or URLs of the devices to which the calls will be forwarded. These URLs must have one of these formats: 
    • sip: nº of username@sip.fermax.com, in case of diversions to mobile using the MEET-ME APP, where username corresponds to the parameter username of the MEET-ME account installed in the mobile. Select the MEET ME check box if you want MEET ME icon show in the monitor.
    • sip: XXX@ip_address, in the case of diversions to MEET devices in the installation itself, where XXX is the device number and IP_address is the IP address of that device.              
    • sip: user@domino_server_sip, in case of diversions to a third-party SIP device.         
       
  • AUTO ANSWER: Check this box if you want the monitor to automatically pick up when a call is received, if it is not answered manually within 10 seconds.
  • OUN (GPON): Used in large installations based on SIP protocol (GPON) and in combination with the configuration of said installations.
  • DTMF UNLOCK: Generally, panels using SIP protocol require a number or combination of DTMF numbers to activate the associated door opener.  
    Select this box if the MEET monitor is used in combination with a panel that uses SIP protocol.              
    DTMF KEY: Indicate the DTMF number (or combination of numbers) to be generated when the monitor's door open button is pressed, to activate the calling SIP panel's door opener. They can be numeric characters and special characters such as # or *.
    • NUMBER OF CAMERAS: Numbers of IP cameras related to the panel, that will be available to switch during panel call. (0-4 optional).

No. OF DOOR LOCKS: Indicate the number of door openers that this monitor will control. (Between 0 and 4). Depending on the number indicated, Can define the Text of the relay, the monitor screen will display Key icons or Text when the monitor receives a call from block panel or 1W panel. These options only can show key icon when the call from general entrance panel.

NOTE:
Additional door openers are connected to a 2-Relay MEET Module Ref.1490, 4-Relay Meet Module Ref. 1491 connected to panel nº 1 of the block or Panel Realy where the monitor is installed (MILO DIGITAL, MARINE MEET or KIN panels only).

 
 

Actuator

 
 

PIN CODE

 
 

Management

 
 

Complementary information

Installation of thirds-party applications

In order to enable and use a third-party APP, it must first be installed on the monitor.

The APP to be installed must be previously verified and signed by FERMAX ELECTRONICA.  It is not possible to directly install APPs with *.apk format.                                                                                                                         
Contact FERMAX's After-Sales Service in the event that you wish to install a specific APP in a MEET monitor, to verify its viability.                                                                                                                                                                
 If it is viable, you will receive two files with extension *.img, one of them to install the APP and another one of them to uninstall it if necessary. 

The procedure to install or uninstall the APP through a PC connected to the same LAN as the monitor, and using the MEET System Upgrading Tool.exe program, is as follows:

  1. Start the MEET System Upgrading Tool V01.00.exe
    Imagen que contiene captura de pantalla

Descripción generada automáticamente
  2. Browse the PC to find the location of the *.img file corresponding to the installation of the APP.
  3. Indicate the IP of the monitor.
  4. Select UPGRADE.

The application will be installed in a few seconds, and will be ready to be enabled on the monitor, as explained in section 4.5 Enable third party APP.

NOTE:
The process of uninstalling an APP is similar to the installation process, but using the uninstall *.img file.
Use MEET System Upgrade Tool V1.2.exe instead of MEET System Upgrade Tool V1.00.exe for the installation of an APP on a batch of MEET monitors. Both programs can be downloaded from the FERMAX website.

 
 

Firmware updates

NOTES:
Use MEET System Upgrade Tool V1.2.exe instead of MEET System Upgrade Tool V1.00.exe to upgrade a batch of MEET monitors. Both programs can be downloaded from the FERMAX website.

 
 
monitor setup installation tool

Download Article

Table of Contents

Description Installation Stand placement Attaching the monitor to the stand Configuring diagram Wired alarm and doorbell sensors Wiring of FERMAX MEET Relay Module Ref. 1616 Local programming from the monitor Installer access Basic configuration of the monitor Configuring the alarm settings Enable/disable functions Enable/disable function icons on the monitor Change installer pin Web browser programming Device General Network configuration IP Camera SIP Advanced Actuator PIN CODE Management Complementary information Installation of thirds-party applications Firmware updates

Related Articles

  • NEO Monitor Installer
  • WIT A10/A Monitor User
  • 970201 Neo monitor user manual

For more information, visit www.fermax.com
Contact: tec@fermax.com www.fermax.com/contact

Fermax logo

FERMAX ELECTRONICA S.A.U

Avenida Tres Cruces, 133
46017 Valencia, Spain

Expand