970089 WIT A10/A Monitor Installer Manual
Written by Tecnico Internacional
Updated at January 19th, 2026
Description
The following document is the Installation Manual for the FERMAX MEET range monitors, corresponding to WIT A10/A monitor V03.70.

The monitor includes the Android 10 operating system and allows the installation of third-party applications. Fermax is not responsible for any incompatibilities with the hardware or operating system if the installer has installed an application that requires additional components, more powerful hardware or a version higher than Android 10. Likewise, even if the application works initially, future updates may no longer be compatible for the same reasons.
Installation
Stand placement
Attaching the monitor to the stand
Configuring diagram
The MEET monitor is connected to the installation by means of connectors: ethernet for LAN connection and MOLEX type connectors for other connections (power supply, RS-485 and sensor inputs).
A bag containing the corresponding male plugs with their cables is enclosed with the monitor´s connector

- MEET Static IP: Ethernet connector to the building's LAN installation. PoE for WIT monitors.
- APRTMENT Dynamic IP: Ethernet connector to the home’s local LAN installation. Only WIT 10” monitor.
- +12V: 12 Vdc power input for non-PoE installations.
-
Siren / Sensors:
-
S: 12 Vdc auxiliary output synchronised with the activation of any sensor.
The maximum current is 100 mA. - -: GND.
- Z1-Z7: sensor inputs. Z8 is reserved for tamper.
-
S: 12 Vdc auxiliary output synchronised with the activation of any sensor.
- 12V +,-,485+,485-: Power output and RS-485 connection for the 10 Relay Module Ref. 1616.
NOTE:
APRTMENT Dynamic IP connection requires a DHCP server, as it is not possible to assign an IP address from the monitor.
Wired alarm and doorbell sensors
Wiring of FERMAX MEET Relay Module Ref. 1616
Local programming from the monitor
Installer access
Basic configuration of the monitor
Configuring the alarm settings
Enable/disable functions
Enable/disable function icons on the monitor
If a third-party application (APP) has been installed,
Touch the icon
to enable a previously installed APP according to the procedure indicated in section Installation of third-party applications.
Change installer pin
Web browser programming
Device
General
Network configuration
IP Camera
SIP
Advanced
The MEET monitors allow you to divert your calls to other devices such as:
- Other MEET monitors in the installation
- SIP devices
- Mobile phones (via MEET-ME APP)

-
SIP EXT.: Use this drop-down to set up call forwarding from this monitor to other devices (NONE, 1, 2, 3 or 4). The form will be automatically adapted depending on the number chosen.
Indicate the URL or URLs of the devices to which the calls will be forwarded. These URLs must have one of these formats:- sip: nº of username@sip.fermax.com, in case of diversions to mobile using the MEET-ME APP, where username corresponds to the parameter username of the MEET-ME account installed in the mobile. Select the MEET ME check box if you want MEET ME icon show in the monitor.
- sip: XXX@ip_address, in the case of diversions to MEET devices in the installation itself, where XXX is the device number and IP_address is the IP address of that device.
-
sip: user@domino_server_sip, in case of diversions to a third-party SIP device.
- AUTO ANSWER: Check this box if you want the monitor to automatically pick up when a call is received, if it is not answered manually within 10 seconds.
- OUN (GPON): Used in large installations based on SIP protocol (GPON) and in combination with the configuration of said installations.
-
DTMF UNLOCK: Generally, panels using SIP protocol require a number or combination of DTMF numbers to activate the associated door opener.
Select this box if the MEET monitor is used in combination with a panel that uses SIP protocol.
DTMF KEY: Indicate the DTMF number (or combination of numbers) to be generated when the monitor's door open button is pressed, to activate the calling SIP panel's door opener. They can be numeric characters and special characters such as # or *.- NUMBER OF CAMERAS: Numbers of IP cameras related to the panel, that will be available to switch during panel call. (0-4 optional).
No. OF DOOR LOCKS: Indicate the number of door openers that this monitor will control. (Between 0 and 4). Depending on the number indicated, Can define the Text of the relay, the monitor screen will display Key icons or Text when the monitor receives a call from block panel or 1W panel. These options only can show key icon when the call from general entrance panel.

NOTE:
Additional door openers are connected to a 2-Relay MEET Module Ref.1490, 4-Relay Meet Module Ref. 1491 connected to panel nº 1 of the block or Panel Realy where the monitor is installed (MILO DIGITAL, MARINE MEET or KIN panels only).
Actuator
PIN CODE
Management
Complementary information
Installation of thirds-party applications
In order to enable and use a third-party APP, it must first be installed on the monitor.
The APP to be installed must be previously verified and signed by FERMAX ELECTRONICA. It is not possible to directly install APPs with *.apk format.
Contact FERMAX's After-Sales Service in the event that you wish to install a specific APP in a MEET monitor, to verify its viability.
If it is viable, you will receive two files with extension *.img, one of them to install the APP and another one of them to uninstall it if necessary.
The procedure to install or uninstall the APP through a PC connected to the same LAN as the monitor, and using the MEET System Upgrading Tool.exe program, is as follows:
-
Start the MEET System Upgrading Tool V01.00.exe

- Browse the PC to find the location of the *.img file corresponding to the installation of the APP.
- Indicate the IP of the monitor.
- Select UPGRADE.
The application will be installed in a few seconds, and will be ready to be enabled on the monitor, as explained in section 4.5 Enable third party APP.
NOTE:
The process of uninstalling an APP is similar to the installation process, but using the uninstall *.img file.
Use MEET System Upgrade Tool V1.2.exe instead of MEET System Upgrade Tool V1.00.exe for the installation of an APP on a batch of MEET monitors. Both programs can be downloaded from the FERMAX website.
Firmware updates
NOTES:
Use MEET System Upgrade Tool V1.2.exe instead of MEET System Upgrade Tool V1.00.exe to upgrade a batch of MEET monitors. Both programs can be downloaded from the FERMAX website.
Download Article