Description

[Meet panel] Description note (mifare)
NOTE:
Residents can access to their corresponding entrance by passing their authorized Mifare identifier(not available for 7-byte cards).. The door will open and release the lock.
The Mifare identifier data must be added through FERMAX MEET MANAGEMENT software. Maximum 100.000 identifiers.
By means of their WIEGAND connection (output) it is possible to integrate this Mifare reader in third party Access Control Systems. It is also possible to integrate third party readers using WIEGAND protocol with the panel.
Functions introduccion
- Call apartment
- Open door, relay delay settings
- Connect exit button
- Speech message for release lock
- Door opened alarm
- Tamper alarm
- Alarm management by access control (only panel with proximity reader)
- Work mode
Call apartment
Visitor push the pushbutton for calling in the 1W Panel, the ring back tone will be sent, meanwhile the monitor will ring. The monitor will show video and can conversation after answer, then release lock.
Web browser programming
The 1W panel has an integrated web server, which allows to configure the parameters. This web server is accessed via the panel’s IP address.
The browser opens with the configured IP address of the panel. A screen opens requesting a username and password.
- Default IP: 10.1.1.2
- Username: admin
- Password: 123456
Device
The following information is displayed: device name, firmware version, MAC address, IP address about the panel.

General
The section GENERAL allows the configuration of the identification parameters of the 1W MILO panel within the installation.
It allows time-date configuration.

TYPE: Select the identification parameter of the panel. There are some other parameters related, depending on TYPE selection.
General entrance panel
Panel installed in one of the main entrances to a condominium.

[Meet panel] General entrance panel
-
DEVICE NUMBER: Number assigned to the general entrance where this panel is installed (1-9000).
In the case that there is one entrance only, leave the default value 1. - DEVICE TAG: Text to be shown in the monitor and guard unit.
- CONGIERGE: The number of concierges can be assigned to each concierge from 9901 to 9998, depending on the installation.
Block panel entrance
Panel installed in a single building or in a block of a condominium.

[Meet panel] Block Panel Entrance webserver
- BLOCK: Number assigned to the block where the panel has been installed (1-999). In the case of individual blocks, let the default value: 1.
- DEVICE NUMBER: Number assigned to the block entrance where this panel is installed (1-99). In the case that there is one entrance only, leave the default value. 1.
- DEVICE TAG: Text to be shown in the monitor and guard unit.
- CONGIERGE: The number of concierges can be assigned to each concierge from 9901 to 9998, depending on the installation.
1 Way panel
For a single house or apartment. It can only call to a unique apartment.

[Meet panel] 1 way panel webserver
- BLOCK: Number assigned to the block where the house or apartment belongs (1-999). In the case of individual apartments or houses, leave the default value: 1.
- APARTMENT: Apartment number where this panel is installed. (0001-9899)
- DEVICE NUMBER: Number assigned to this panel (1-9). In the case that there is one panel only, leave the default value 1.
- DEVICE TAG: Text to be shown in the monitor and guard unit.
VIDEO RESOLUTION: To fit the different types of monitors. The default value 640×480
PANEL VOLUME: Select the desired value between 1 and 5. Default option is 5
This volume for voice synth and click tone when the audio of panel close.
[Meet panel] VOICE SYNTH general webserver
VOICE SYNTH:Enables or disables the speech when door lock is released. If the speech is disabled, no speech in the panel will sound when the lock is released.
[Meet panel] Language general webserver
LANGUAGE: Select the desired language in the dropdown options.
Default option is ENGLISH.
Refresh the webpage after changing the language
If select CUSTOM, the custom language will available if the custom language file be imported, the default language (selected language in FROM ) will available if no custom language file is be imported.
The panel will reboot if the custom language be imported or be deleted
The language file include KEY, DEFAULT STRING, CUSTOM STRING and REMARK.
Do not modify KEY, DEFAULT STRING and REMARK.
The language in default string of exported language file base on selected language in FROM.
CUSTOM STRING is new description, empty or *, the default string still is available if the custom string is empty, do not display anything if the custom string is *.
REMARK prompt that some characters do not require translation.
The VOICE PROMPT file is available when the CUSTOM is be selected, otherwise the voice prompt is default.
- DATE FORMAT: Format to show the date information in the screen.
- DATE: Setting date manually (See NOTE below).
- TIME: Setting time manually (See NOTE below).
- TIME ZONE: Setting the time zone of panel. Select local time zone and save.
- DAYLIGHT SAVING TIME: Shall be enabled for DST periods and disabled for wintertime.
If the project has no management software the installer can set date, time and time zone manually. If the project has management software, the date and time of panel will synchronizes automatically with the management software. If the panel has access to internet, the date and time of panel will also synchronize with internet time server.
NOTE:
1.TIME ZONE is usable only when the time is automatically taken from internet or FERMAX MANAGEMENT SOFTWARE.
2. Date and time can’t be saved after power loss, the time zone and date format can be saved.
3. The webserver will show “TOTAL: XXX RECORD(S) IMPORTED” when the language file is be imported.
Network configuration
[Meet panel] Network configuration webserver
IP: IP address to be assigned to this panel.
MASK: Subnet mask corresponding to the LAN
GATEWAY: LAN gateway
DNS: DNS server address. In case of doubt, we recommend using the default value 8.8.8.8.
SOFTWARE IP: IP address of the PC where the MEET Management Software is installed (if any).
SOFTWARE PIN: PIN ACCESS code for the Management Software control. The default setting is 123456. Indicate the corresponding parameters and click on SAVE to confirm.
NTP SERVER IP: The date and time will synchronous with the NTP server If the panel has access to internet, the default NTP server is pool.ntp.org.
NOTE:
The MEET system uses static IP addressing. This ensures that each device has a unique IP address in the same installation.
If a device has an IP address already assigned to another device on the network, an "IP CONFLICT" prompt will appear in the panel screen, along with the MAC of the conflicting device.
Both devices will not work properly until this issue is resolved.
If a device has an IP address already assigned to another device on the network,
Both devices will not work properly until this issue is resolved.
Access
DOOR RELAY TIME: Time for lock-release relay remains active (1-9s optional).Time for lock-release relay remains active (1-9s optional).
[Meet panel] Open door delay acces webserver
OPEN DOOR DELAY: The time that the open-door command has be sent and the relay is not activated. The relay will active after the DOOR DELAY TIME be set, Open door relay is useful when the door is not close the panel. (option 0-9 s)
ADMIN CARD: Admin/master card ID registered to enrol additional prox cards. This option is useful when there is not MEET MAGEMENT SOFTWARE available.
When there is no management software, enter 0000 if you do not know the ID of the admin card. The first MIFARE prox card detected by the reader will act as admin/master card. The card of the residents can be added afterwards.
To program user cards, present the admin/master card previously created on the card reader. The panel will enter in cards program mode. All the cards presented from now on will automatically updated in the panel and may be used to open the door.
If there are not more cards to program, after two minutes the panel will exit program mode.
There is not possible to deregister cards programmed by this method. Use the FERMAX MEET MANAGEMENT SOFTWARE for full operational possibilities.
DISARM BY CARD:When an already programmed user card is presented to the reader, and it has been previously assigned to a monitor, the alarm system of the corresponding apartment will change to HOME mode.
ACCESS PIN: No function.

IP Camera
[Meet panel] IP Camera webserver
The monitor can switch to IP CCTV camera video during a conversation. This function allows to configure IP CCTV cameras using RTSP protocol to be displayed as an auxiliary camera to provide different view angles from the door or related areas.

NUMBER OF CAMS: IP camera Number. Up to 4 different cameras.
- CAMERA 1, 2, 3 and 4: IP camera name.
- URL: -> rtsp://user:password@Ip_adress_of_camera
user: password -> for cameras that require a username and password for connection.
Depending on the brand/model of camera, other URL different than the one above would be required. Check the IP camera technical documentation.
MAIN VIDEO STREAM: Main video stream can from panel camera or from IP camera.
SIP
This option allows to configure 1W panel to use SIP functions, such us call divert to smartphone using the FERMAX MEET ME APP or allows the panel to operate with a third-party SIP systems or terminals using SIP protocol instead of FERMAX MEET protocol.
ENABLE SIP: Select this box to enable SIP functions.
SEARCH SIP STATUS: this button appears when enabling SIP function, shows SIP REGISTERED if the panel register successfully or SIP REGISTER FAILED if the panel register unsuccessfully.
SIP SERVER: Indicate the sip SERVER address. Format -> sip: IP_SERVER
DOMAIN: domain of the SIP server or IP address.
STUN IP: domain of the SIP server.
STUN PORT: Used for the configuration of Internet SIP server-based installations. It is usually port 5060. Check with your network or SIP server administrator.
TRANSPORT: UDP, TCP, TLS options. Default UDP, the No. port of UDP is 5060, the default port is 5060 if no port at the back sip:sip.fermax.com, the No. port of UDP is 5223, the No. port of TLS is 4443
SIP USER, SIP PASSWORD: Indicate the user and password that this terminal is programmed in the SIP server.
CONVERSATION, RING TIME: No function.
NOTE: When the panel is used as a sip device, use quick dial to call SIP devices or receive calling of other SIP devices, SIP function must be enabled.

SIP Call
[Meet panel] SIP Call webserver
This option allows to generate calls to smartphone devices in the cases where it is not a MEET monitor associated in the installation. A FERMAX MEET ME licence Ref. 1496 is required for each apartment
The call can be received in 8 smartphones simultaneously.
Furthermore, it is also possible, to generate simultaneous calls to several devices MEET and/or third-party SIP devices as well, using SIP protocol instead of FERMAX MEET protocol.
A .CSV file containing the associated number and the information of the diverted device or devices must be updated in the panel.
SIP DIVERT MODE: This function is available for the device of sip call list. Please refer to SIP section for further details.
- PARALLEL CALL: When the panel calls the resident, the monitor and the call divert APP in sip call list rings at the same time. Once a terminal answers, the call in the other one stops ringing.
- SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring 30s. If no answer, the call will be diverted to MEET ME APP or other associated devices.
APARTMET: The panel calls the resident.
NUMBER: The monitor, the call divert APP and sip device.
DELETE: Delete Apartment and number.

Advanced
Quick dial is associated a monitor, guard unit or sip terminal.
QUICK DIAL: Enable or disable quick dial function.
NOTE: The quick dial work when the panel is general panel or block panel, the panel do not call concierge.
URL: If call device of MEET system, URL: sip: sip account @ IP address of MEET device, the sip account is optional. If call SIP device, URL: sip: sip account @ IP address of sip server
ONU (GPON): Enable or disable the SIP penetration firewall function.

Pincode
[Meet panel] PINCODE webserver
It allows you to change the INSTALLER PIN code, to access the installation configuration parameters through a web browser.

Enter the current code, the new pin and confirm it.
The new password can have alphanumeric characters and has no limit on its length.
Finally, select SAVE.
NOTE:
Make a note of the new PIN at your convenience. If you lose or forget your PIN, you should contact FERMAX's Technical Department to receive instructions regarding its recovery. All settings programmed into the panel will be lost after recovery.
Management
[Meet panel] Management webserver
Use this functionality to import, export configuration file, reboot remotely the panel, return it to factory settings, or log out webserver

CONFIGURATION FILE: Allow installers to save a backup of its configuration via export button, later apply that previously exported file via import button to the same or a different KIN panel with same version.
- The exported configuration file do not include imported picture, the language file ,directory file and sip call file.
- Press import button, the pop will appear.

- Press SKIP, the general settings from be imported configuration file, if the general settings is different with imported configuration file, modify general settings and press OK.
RESTORE FACTORY SETTINGS: All the settings are restored to the factory settings. The IP address will be changed to the default IP: 10.1.1.2.
[Meet panel] Management reboot + log out webserver
REBOOT DEVICE: The panel will automatically turn off and start up keeping all the programming parameters.
When resetting, the device will lose connection with the PC. Refresh the website after about 60 seconds to resume the connection.
LOG OUT: Press OK and log out webserver, appear interface of log in.
Operation
1W Panel
The mode of associate concierge is to disable Monitoring or NIGHT, Visitor push the pushbutton for calling in the 1W Panel, the ring back tone will be sent, countdown time in the monitor from 30s meanwhile the monitor will ring. The monitor will show video and can conversation after answer, then release lock.
The mode of associate concierge is to enable Monitoring, Visitor push the pushbutton for calling in the 1W Panel, the ring back tone will be sent, countdown time in the monitor from 15s meanwhile the monitor will ring. The monitor will show video and can conversation after answer, then release lock, the calling will transfer to concierge if the monitor doesn’t answer or doesn’t release lock.
The mode of associate concierge is DAY, Visitor push the pushbutton for calling in the 1W Panel, the ring back tone will be sent, the call will transfer to concierge.
The Concierge can transfer the call from 1W panel.
Block panel
The panel will call concierge when the visitor pushes the pushbutton, the panel send special sound if the concierge with NIGHT mode or general concierge enables ONLY RECEIVE.G.E. PANESL CALLS.
The panel can call concierge with other mode.
The Concierge can transfer the call from block panel.
General entrance panel
The panel will call concierge when the visitor pushes the pushbutton, the panel send special sound if the concierge with NIGHT mode.
The panel can call concierge with other mode.
The Concierge can transfer the call from block panel.
Installation and diagrams
Flush box installation

Installation guide diagram
- Flush installar
- Base flush box depth adjustment hook.
- The upper part of the panel is stuck in, then move the panel to the flush box.
- Move the slider of the panel and fix the two screws, when installing, pay attention to the reservation of the 1.7CM space around the door to move the slide cover.

Connector
The 1W PANEL is connected to the installation by means of connectors: Ethernet for LAN connection and MOLEX type connectors for other connections (power supply, RS-485, etc.). A bag containing the corresponding female connectors with their cables comes with the panel.

POWER INPUT: 12 Vdc power supply for the cases where no LAN PoE is available.
OUTPUT: Electric lock control relay output.
- NC: Normally closed contact
- NO: Normally opened contact
- C: Common
Exit Button / Door Sensor.
- (EXIT, -) Connections for indoor button
- (DS, -) Connection for door opened sensor
RJ 45 Network
- RJ-45 LAN or LAN PoE connection
NOTE:
Installing a door open sensor in DS, an alarm sounds in the panel and concierge if the door remains opened during 120s.
The panel has an internal tamper button. If the panel is separated from the wall, an alarm is triggered in the panel, concierge (if exists).
Tamper installation
[Meet panel] Tamper installation

Firmware updates
[MEET panel] Firmware updates
Sometimes it may be necessary or convenient to update a new firmware version because improvements or corrections have been incorporated into its operation.
FERMAX's Technical Department periodically informs (through Communications, Technical Bulletins, etc.) about the release of a new firmware update, as well as the improvements incorporated.
Contact the FERMAX Technical Department if you wish to receive the corresponding update file.
The firmware update is performed via the FERMAX MEET System Upgrading Tool V01.00.exe. The procedure for updating the firmware with the corresponding update file is as follows:
- Start the FERMAX MEET System Upgrading Tool v1.00. exe.
- Click on “…” button and browse the PC to find the corresponding .IMG update file.
Up to 3 .IMG files can be selected at the same time (for the case of the update has more than unique .IMG file). - Indicate the IP Range of the panels.
- Click on “Start”.
The new firmware will be installed, and the panel will restart automatically.
RTSP Streaming from outdoor panel
[Meet panel] RTSP STREAMING FROM OUTDOOR PANEL
Using an external element (PC/Tablet/Smartphone) connected to the network makes it possible to access the panel’s built-in camera via RTSP protocol with the following address:
rtsp://admin:password@Panel_IP:8554/ch01
admin: admin
password: 123456 (Default), if it has been changed we will use the current password.
Panel_IP: Current IP adress of the panel.
It is possible to access using VLC as in the image below:

Regulation
FERMAX ELECTRÓNICA, S.A.U. declares that this product complies with the requirements of:
RED 2014/53/EU Directive “Radio frequency equipment”
Radio frequency module:
• Frecuencia: 13.56MHz / Potencia máxima: 2,45mW