Table of Contents

Description [Meet panel] Description note (mifare) Web browser programming Device General Directory Network configuration Access Face recognition Lift IP Camera SIP SIP Call Advanced Pincode WeChat QR Management Operation Icon functions Face recognition icon QR code icon Directory icon Guest code icon Access pin icon Mode function Transfer function Installation and diagrams Firmware updates

Description

MARINE PANEL REF. 1455 V03.70

 
 

MILO DIGITAL VIDEO PANEL POE MEET REF. 1832 V03.70

 
 

[Meet panel] Description note (mifare)

NOTE:
Residents can access to their corresponding entrance by passing their authorized Mifare identifier(not available for 7-byte cards).. The door will open and release the lock.
The Mifare identifier data must be added through FERMAX MEET MANAGEMENT software. Maximum 100.000 identifiers.
By means of their WIEGAND connection (output) it is possible to integrate this Mifare reader in third party Access Control Systems. It is also possible to integrate third party readers using WIEGAND protocol with the panel.

Web browser programming

[Meet panel M-K] Web browser programming

For programming of the panel, access is required through a PC via a web browser. Preferably use Chrome browser.

The PC must be connected to the same LAN as the panel and configured with an IP address in the same range. The panel default IP address is 10.1.0.1.  

Type the IP address of the panel in the address bar of the browser. An identification form will appear.

The default identification data are:

User name: admin

Password: 123456

 

 

A web page will appear with the different programming sections:

 

Device

[Meet panel M+K] Device webserver

The section DEVICE provides technical information regarding the equipment, as a reference.

  • FERMAX MEET PANEL (A4/C): Device type.
  • FIRMWARE: Version of the installed firmware.
  • DEVICE: Type and panel number.
  • MQTT ID:MQTT ID of the panel.
  • MAC: Panel MAC number.
  • IP: IP address assigned to the panel.

 

 

 

 

 

 

 
 

General

The section GENERAL allows the configuration of the identification parameters of the MILO panel within the installation.

It allows time and date configuration.

TYPE: Select the identification parameters of the panel. There are some other parameters related, depending on TYPE selection:

General Entrance Panel

Panel installed in one of the main entrances to a condominium.

[Meet panel] General entrance panel

  • DEVICE NUMBER: Number assigned to the general entrance where this panel is installed (1-9000).   
    In the case that there is one entrance only, leave the default value 1.
  • DEVICE TAG: Text to be shown in the monitor and guard unit.
 
 

Block Panel Entrance

 

[Meet panel] Block Panel Entrance  webserver

  • BLOCK: Number assigned to the block where the panel has been installed (1-999). In the case of individual blocks, let the default value: 1.
  • DEVICE NUMBER: Number assigned to the block entrance where this panel is installed (1-99). In the case that there is one entrance only, leave the default value. 1.
  • DEVICE TAG: Text to be shown in the monitor and guard unit.
 
 

1 Way panel

For a single house or apartment. It can only call to a unique apartment.

[Meet panel] 1 way panel webserver

  • BLOCK: Number assigned to the block where the house or apartment belongs (1-999). In the case of individual apartments or houses, leave the default value: 1.
  • APARTMENT: Apartment number where this panel is installed. (0001-9899)
  • DEVICE NUMBER: Number assigned to this panel (1-9). In the case that there is one panel only, leave the default value 1.
  • DEVICE TAG: Text to be shown in the monitor and guard unit.
 
 

PANEL VOLUME: Select the desired value between 1 and 5. Default option is 4.

The conversation volume is common for uplink and downlink.

[Meet panel] VOICE SYNTH general webserver

VOICE SYNTH:Enables or disables the speech when door lock is released. If the speech is disabled, no speech in the panel will sound when the lock is released.

VIDEO RESOLUTION: In order to fit the different types of monitors. The default value 640×480 

STANDBY INTERFACE: The standby image is customizable and can be imported, exported, or deleted. The default standby image can’t be exported and deleted.

CALL CONCIERGES:

  • DIAL BELL TO CALL: The visitor presses directly bell button that will call the concierge.
  • DIAL NUMBER TO CALL: The visitor enters No. of concierge that show in the panel and press bell button will call the concierge.
  • NO CONCIERGE: No concierge information in the display.

CONCIERGES: The number of concierges can be assigned to each concierge from 9901 to 9998, depending on the installation.

It is also possible to call other concierges than the ones indicated in the panel dialling the concierge number through the keypad.

[Meet panel] Language general webserver

LANGUAGE: Select the desired language in the dropdown options. 

图形用户界面, 文本, 应用程序

AI 生成的内容可能不正确。[JX1] 

Default option is ENGLISH.    
Refresh the webpage after changing the language

If select CUSTOM, the custom language will available if the custom language file be imported, the default language (selected language in FROM ) will available if no custom language file is be imported.

The panel will reboot if the custom language be imported or be deleted 

The language file include KEY, DEFAULT STRING, CUSTOM STRING and REMARK.

Do not modify KEY, DEFAULT STRING and REMARK.

The language in default string of exported language file base on selected language in FROM.

CUSTOM STRING is new description, empty or *, the default string still is available if the custom string is empty, do not display anything if the custom string is *.

REMARK prompt that some characters do not require translation.

The VOICE PROMPT file is available when the CUSTOM is be selected, otherwise the voice prompt is default.

  • DATE FORMAT: Format to show the date information in the screen.
  • DATE: Setting date manually (See NOTE below).
  • TIME: Setting time manually (See NOTE below).
  • TIME ZONE: Setting the time zone of panel. Select local time zone and save.
  • DAYLIGHT SAVING TIME: Shall be enabled for DST periods and disabled for wintertime. 

NOTES: 

If the installation has FERMAX MANAGEMENT SOFTWARE, the date and time of panel will synchronize automatically with the management software. If the panel has access to internet, the date and time of panel will also synchronize with internet time server.

If the installation has no FERMAX MANAGEMENT SOFTWARE the installer can set date, time and time zone manually. Do not use the GMT (TIME ZONE) adjustament in this case. GMT is usable only when the time is automaticaly taken from internet or FERMAX MANAGEMENT SOFTWARE. 

Date and time are not saved after power loss, unless there were internet or managament software in the installation. However, the time zone, date format and daylight-saving time can be saved anyway.

Pay attention to the SAVE button related to panel settings or date/time settings since are different and independent.

 
 

Directory

The section DIRECTORY allows the configuration of agenda,the panel allows to use a directory for calling the tenants. 

  • MAPPING CALL: The installer can create a mapping call list. Mapping call codes can include numbers and letters . For block panels, 1-5 digits is allowed, for general entrance panel, 1-8 digits is allowed.
    The visitor can call the apartment via mapping code only if this apartment has mapping code enabled, the visitor can call apartment via apartment number if this apartment does not have a mapping code.
  • WHITE LIST: the apartment can be called if the corresponding white list of apartment is Y (YES), otherwise, the apartment cannot be called.
  • DIRECTORY CALL: MILO panel allows to use a directory for calling the tenants. Visitors can select the tenant’s name from this directory and call directly without knowing the apartment number.

A .CSV table with the name of the tenants and apartment numbers shall be created.

The operation procedure to generate and uptade the .CSV file is as follow:

  1. Select export button to generate a blank .CSV table, an save it in your PC.        
    Rename this table as your choice or leave the default name MEET AGENDA PXXX-YY.csv.          
  2. Use Microsoft Excel / Notepad or Notepad++ (recommended) to open the created file. It will have a look like this:
  3. The first cell (A1) has the content: APARTMENT, The second cell (B1) has the content: NAME, The third cell (C1) has the content: MAPPING CODE, The fourth cell (D1) has the content: WHITELIST(Y), the fifth cell (E1) has content: DESCRIPTION.    
    Do not change it.
  4. Use the following cells (A2, A3, A4, etc.) to fill in the data of apartment name, user’s name, mapping code, whitelist and description, with the format “Apartment number”, “Name”, “Mapping code”, “Whitelist(Y)”, “DESCRIPTION”. If Mapping or Whitelist is not used the format remains the same, all 5 commas are needed. Check with Notepad / Notepad++ that the format is properly kept as per the picture.
  5. Once the table has been finished, save it and import to the panel.  For this, click on import button, select the file to import .
    Wait for until a pop up message “TOTAL: xxx RECORD(S) IMPORTED” appears, The invalid data do not be imported.
  6. Press delete button , imported agenda file can be deleted.

RESIDENT SEARCH: The visitor can search faster the tenant via shortcut if the function is enabled.

EXAMPLE

           手机屏幕截图

AI 生成的内容可能不正确。

NOTE:
In the case of non-Latin alphabets (for example: Chinese, Russian / Cyrillic, Arabic, Hebrew etc.), the procedure is as follows:

  1.  From the web server of the panel, export the empty .CSV file.
  2.  Open with Windows Notepad and copy the directory list of the CSV file in the notepad with the desired alphabet (Latin, Chinese, Russian / Cyrillic, Arabic, ...). 
  3.  Save the file as .CSV / all files *. * / UTF-8
  4.  From the panel´s webserver, import this file and wait for the message " TOTAL: xxx RECORD(S) IMPORTED" to be displayed. the panel will lock during importing. 
  5.  Maximum 10,000 lines in be imported agenda list.
  6.  Do not use special characters such as “– “on the names or perhaps the upload process on the panel will not perform properly.
  7.  If the agenda list is empty , the message ” TOTAL: 0 RECORD(S) IMPORTED" to be displayed.

In the case of non-Latin writing systems, it is recommended NOT to use Microsoft Excel since there is a risk of altering the format of the directory file and that the content of the directory is not loaded correctly.

 
 

Network configuration

[Meet panel] Network configuration webserver

IP: IP address to be assigned to this panel.

MASK: Subnet mask corresponding to the LAN 

GATEWAY: LAN gateway

DNS: DNS server address. In case of doubt, we recommend using the default value 8.8.8.8.

SOFTWARE IP: IP address of the PC where the MEET Management Software is installed (if any).

SOFTWARE PIN: PIN ACCESS code for the Management Software control. The default setting is 123456. Indicate the corresponding parameters and click on SAVE to confirm.

NTP SERVER IP: The date and time will synchronous with the NTP server If the panel has access to internet, the default NTP server is pool.ntp.org.

NOTE: 
The MEET system uses static IP addressing. This ensures that each device has a unique IP address in the same installation.  
If a device has an IP address already assigned to another device on the network, an "IP CONFLICT" prompt will appear in the panel screen, along with the MAC of the conflicting device.       
Both devices will not work properly until this issue is resolved.

 
 

Access

This section allows some programmings related to the access control functionallity of the panel. 

 

[Meet panel M+K] Acces panel relay time webserver 

PANEL RELAY TIME: Time for lock-release relay remains active (1-9 s optional).

OPEN DOOR DELAY: The time that “open the door “command has be sent and the relay is not activated. The relay will active after the DOOR DELAY TIME be set, Open door relay is useful when the door is not near to the panel, the visitor has time to reach the door (option 0-9s).

[Meet panel M+K] relays, egress, admin car Acess webserver

2 RELAY MODULE: REF.1490 2 RELAY

  • OPEN DOOR DELAY 0#: can’t be set, sync open door delay of panel.
  • OPEN DOOR DELAY 1#: The time that the open-door command has be sent and          the relay is not activated. The relay will active after the DOOR DELAY TIME be set, Open door relay is useful when the door is not close the panel. (option 0-9 s)

4 RELAY MODULE: Only available in panel programmed as PANEL 1.                
4 relay module (Ref. 1491 4 relay) must be connected to the RS485 port of the panel No.1. See INSTALLATION section for further details.

  • 1#-4# RELAY TIME: Time that the corresponding additional door relay keeps active (1-9s optional).
  • 1#-4# OPEN DOOR DELAY: The time that the open-door command has be sent and the relay is not activated. The relay will active after the DOOR DELAY TIME be set. Open door relay is useful when the door is not close the panel. (option 0-9 s).

EGRESS BUTTON: The egress button will available if the EGRESS BUTTON is be checked. the relay of panel and Ref.1490 will be activated if the egress button is activated.

PANEL RELAY REPEATER: It activates or deactivates the Ref.1490 2 relay module performance.

OPEN DOOR EXTENSION: DISABLE ,4 RELAY MODULE,2 RELAY MODULE, PANEL RELAY options.

  • 4 RELAY MODULE (REF.1491): associate with Relay 1-4 or CCTV relay in the monitor or Relay 1-4 icon in the concierge.
  • 2 RELAY MODULE (REF.1490): associate with Relay 1 in the monitor or concierge.
  • PANEL RELAY: associate with Relay 1-4 in the monitor.

ADMIN CARD: Admin/master card ID registered to enrol additional prox cards. This option is useful when there is not MEET MAGEMENT SOFTWARE available.               
When there is no management software, enter 0000 if you do not know the ID of the admin card. The first MIFARE prox card detected by the reader will act as admin/master card. The card of the residents can be added afterwards.         
To program user cards, present the admin/master card previously created on the card reader. The panel will enter in cards program mode. All the cards presented from now on will automatically updated in the panel and may be used to open the door.           
If there are not more cards to program, after two minutes the panel will exit program mode.              
There is not possible to deregister cards programmed by this method. Use the FERMAX MEET MANAGEMENT SOFTWARE for full operational possibilities.

DISARM BY CARD: When an already programmed user card is presented to the reader, and it has been previously assigned to a monitor, the alarm system of the corresponding apartment will change to HOME mode.

CARD READ PROMPTS: To disable, no tips when the panel read cards.

GUEST CODE: Guest code function can be enabled or disabled. The panel needs to be connected with a module Ref. 1494 to a third-party Access Control System. See INSTALLATION section.

WIEGAND Protocol used for Wiegand transmission (BURST or 26 BITS). Enter available parameter depending on the third-party Access Control System

FACILITY: Enter available parameter depending on the third-party Access Control System.

QR CODE:Enable or disabled QR code function.

WIEGAND:Protocol used for Wiegand transmission (26 BITS or 34 BITS). Enter available parameter depending on the third party Access Control System.

SITE CODE:The panel will verify site code of QR if the SITE CODE enable. The SITE CODE of QR must be same as filled in.

ACCESS PIN: To enable or disable the activation of the relay for ACCES PIN code.       
UP to 8 different PIN codes per panel. PIN length between 4 to 6 digits.

DOOR OPEN ALARM: An alarm will trigger if the door keeps opened after the programmed DOOR ALARM time. Options: disable, 30s. 60s. 120s, 180s and 250s.

DOOR FORCED ALARM: An alarm will trigger if an abnormal way to open the door has been detected, for example because there has not been any previous “open the door” command.

NOTE: 
his OPEN DOOR DELAY time will not apply to the egress button, door lock release that will be always immediate.

 
 

Face recognition

[Meet panel M+K] Face recognition webserver

Use this setting to enable or disable the FACE RECONGNITION function of the panel.

The FERMAX MANAGEMENT SOFTVARE V01.05 is required for programming and managing the photos of the authorized faces if the model is 5.0.

The FERMAX MANAGEMENT SOFTVARE V01.06/V01.07 is required for programming and managing the photos of the authorized faces if the model is 6.0.

The FERMAX MANAGEMENT SOFTVARE V01.08 is required for programming and managing the photos of the authorized faces if the model is 5.0/6.0.

System supports up to 6,000 faces

图形用户界面, 应用程序

描述已自动生成

FACE RECOGNITION: Enable or disabled face recognition function.

AUTO ACTIVATION: Enable or disabled auto activation function of QR code or face recognition. If enable, Wait 5 seconds for any process to end.

MODEL: 5.0, 6.0 options. Default 6.0.

LIVENESS DETECTION: Enable or disabled LIVENESS DETECTION function.

SIMILARITY: High, medium and low options. Default is low.

NOTE: 
MEET panel face recognition function is based on a bidimensional face identification, with the ability of differentiating among photos or live faces in certain conditions.
This technology can be used to open doors but cannot guarantee the highest security level or 100% accuracy of liveness detection.

If face recognition is enabled, RTSP video streaming will not be available.

 
 

Lift

[Meet panel M+K] Lift webserver

The block panel will show lift dispatch if the LIFT function is enabled.

图形用户界面, 应用程序

描述已自动生成

LIFT DISPATCH:Enable or disabled LIFT DISPATCH function.

WAITING TIME:This time will define the maximum time that the message “Please wait for lift dispatch” will be shown on the display.

The WAITING TIME need be extended based on the delay time of receiving the signal from the elevator to the MEET 32 input module. If the signal is not received within this time on the MEET 32 input module, then the “Please wait for lift dispatch” information on the panel will disappear and a message of “Lift dispatch failed” will be displayed.

NUMBER OF INPUT PORTS:Only available in panel programmed as PANEL 1. according to quantity of lift and block panel, then select number of input ports.

 

 
 

IP Camera

[Meet panel] IP Camera webserver

The monitor can switch to IP CCTV camera video during a conversation. This function allows to configure IP CCTV cameras using RTSP protocol to be displayed as an auxiliary camera to provide different view angles from the door or related areas. 

NUMBER OF CAMS: IP camera Number. Up to 4 different cameras.

  • CAMERA 1, 2, 3 and 4: IP camera name.
  • URL: -> rtsp://user:password@Ip_adress_of_camera
    user: password -> for cameras that require a username and password for connection.
    Depending on the brand/model of camera, other URL different than the one above would be required. Check the IP camera technical documentation.

MAIN VIDEO STREAM: Main video stream can from panel camera or from IP camera.

 
 

SIP

This option allows to configure  panel to use SIP funcionalities, such us call divert to smartphone using the FERMAX MEET ME APP or allows the panel to operate with a third-party SIP systems or terminals using SIP protocol instead of FERMAX MEET protocol.

[Meet panel M+K] SIP webserver

Configuration for smartphone call divert, using FERMAX MEET ME APP                                                    

图形用户界面, 应用程序

描述已自动生成

ENABLE SIP: Select this box to enable SIP functions.

  • SEARCH SIP STATUS: this button appears when enable SIP function, show SIP REGISTERED if the panel register successfully or SIP REGISTER FAILED if the panel register unsuccessfully.

SIP SERVER: Use the FERMAX MEET server -> sip: sip.fermax.com.

DOMAIN: Indicate the server domain -> sip.fermax.com.

OUTBOUND: Not necessary. Leave it in blank.

STUN IP: Not necessary. Leave it in blank.

STUN PORT: Not necessary. Leave it in blank.

H.264: Leave the default value: 102

TRANSPORT: UDP, TCP, TLS options. Default UDP, the No. port of UDP is 5060, the default port is 5060 if no port at the back sip:sip.fermax.com, the No. port of UDP is 5223, the No. port of TLS is 4443

The panel will reboot when the transport is be changed.

SIP USER, SIP PASSWORD: Indicate the user and password of the FERMAX MEET ME licence assigned to this panel. They are indicated in a label attached in the front of the panel.

CONVERSATION, RING TIME: No function.

Configuration for SIP server integration                                                                                                                   

Configure the SIP parameters as explained below, for the cases where the panel works as an extension of a SIP server

图形用户界面

描述已自动生成

Contact with the SIP server administrator to get some of the information required in this section.

ENABLE SIP: Select this box to enable SIP functions.

SEARCH SIP STATUS: this button appears when enable SIP function, show SIP REGISTERED if the panel register successfully or SIP REGISTER FAILED if the panel register unsuccessfully.

SIP SERVER: Indicate the sip SERVER address. Format -> sip: IP_SERVER.

DOMAIN: domain of the SIP server or IP address

OUTBOUND: Not necessary. Leave it in blank.

STUN IP:  domain of the SIP server.

STUN PORT: Used for the configuration of Internet SIP server-based installations. It is usually port 5060.  Check with your network or SIP server administrator.

H.264: Depends on the SIP SERVER. In the case of doubt, leave the default value (102).

TRANSPORT: UDP, TCP, TLS options. Default UDP, the port need match with port of sip server,

The panel will reboot when the transport is be changed.

SIP USER, SIP PASSWORD: Indicate the user and password that this terminal is programmed in the SIP server.

CONVERSATION, RING TIME: No function.

 

 

 
 

SIP Call

[Meet panel] SIP Call webserver

This option allows to generate calls to smartphone devices in the cases where it is not a MEET monitor associated in the installation. A FERMAX MEET ME licence Ref. 1496 is required for each apartment
The call can be received in 8 smartphones simultaneously.

Furthermore, it is also possible, to generate simultaneous calls to several devices MEET and/or third-party SIP devices as well, using SIP protocol instead of FERMAX MEET protocol.

A .CSV file containing the associated number and the information of the diverted device or devices must be updated in the panel. 

SIP DIVERT MODE: This function is available for the device of sip call list. Please refer to SIP section for further details.

  • PARALLEL CALL: When the panel calls the resident, the monitor and the call divert APP in sip call list rings at the same time. Once a terminal answers, the call in the other one stops ringing.
  • SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring 30s. If no answer, the call will be diverted to MEET ME APP or other associated devices. 

[Meet panel M+K] SIP CALL update csv webserver

The operation procedure to generate and update the .CSV file is as follow:

  1. Select export button to generate a blank .CSV table, an save it in your PC.     
    Rename this table as your choice or leave the default name (MEET CALL DIVERT PXXX-YY.csv), where XXX is the BLOCK NUMBER and YY is the device number assigned to this panel).      
  2. Use Microsoft Excel / Notepad or Notepad++ (recommended) to open the created file. It will look like:
  3. The first cell (A1) has the content: APARTMENT, the second cell(B1) has content: NUMBER,  
    Do not change it.
  4. Use the following cells (A2, B2, A3, B3, A4, B4 etc.) to fill in the data of the apartment and number of devices to divert.
    Depending on the type of call, the format of the data is different:
    1. In the case of a call to a FERMAX MEET ME LICENCE:               
      APARTMENT, sip:XXXXXXX@sip.fermax.com where XXXXXXX is the licence username and APARTMENT is the number to be dialled in the panel.
    2. In the case of a call to a MEET device in the same installation:             
      APARTMENT, sip:XXX@IP_DEVICE where XXX is any identifier of the device and IP_DEVICE is the IP address to the MEET monitor to call. 
    3. In the case of a call to a third party SIP device (through a SIP server):               
      APARTMENT, sip:user@IP_SIP_SERVER where user is the identification user that the device to call has been programmed in the SIP server, and IP_SIP_SERVER is the SIP server IP address.
    4. It is also possible to assign multiple and different divert formats to the same apartment (for example a call to a third-party SIP device and a smartphone device as well).   
      Use the corresponding format explained above, using the same row but different column for each format. See example below.
  5. Once the table has been finished, save it and import to the panel.  For this, click on import button, select the file to import,  until a pop-up message “TOTAL: xxx RECORD(S) IMPORTED” appears, the invalid data do not be imported.
  6. Press delete button , imported sip call file can be deleted.

EXAMPLE                                                                                                                                                             

In this example:

  • Apartment 170 generates a call to the monitor IP 192.168.1.190 in the same installation.
  • Apartment 171 generates a call to the smartphone with FERMAX MEET ME licence 0103283.
  • Apartment 645 generates a call to the monitor IP 192.168.1.195 in the same installation.
  • Apartment 180 generates a call to the SIP device 1234 of the SIP server with IP 192.168.1.170.
  • Apartment 181 generates a call to the SIP device 1234 of the SIP server with IP 192.168.1.170 and to the smartphone with FERMAX MEET ME licence 0103283. 
  • Apartment 182 generates a call to the SIP device 1234 of the SIP server with IP 192.168.1.170 and to the monitor IP 192.168.1.195 in the installation.
  • Apartment 183 generates a call to the SIP device 1234 of the SIP server with IP 192.168.1.170 and to the monitor IP 192.168.1.197 in the installation and to the smartphone with FERMAX MEET ME licence 0103283.

NOTE: 
Maximum 10,000 lines in be imported call divert list.
In case the call divert list is empty , the webserver will show “TOTAL: 0 RECORD(S) IMPORTED” when the list is imported.

 
 

Advanced

[Meet panel M+K] Advanced webserver

Some advanced settings, such as sip trunk, can be selected in this section

ENABLE SIP TRUNK: Enable or disable SIP trunk function.

URL: URL of the device:          

Format:
sip: sip_trunk_account@sip_trunk_domain: port    
or 
sip: sip_trunk_account@sip_trunk_ip:port

When there is a VoIP gateway installed on the network connected to a PSTN line.

The panel call can be diverted to user's mobile phone or land line telephone through a voice gateway. 

ONU (GPON): Used in large installations based on SIP protocol (GPON) and in combination with the configuration of said installations.

MAXIMUM DIGITS: only available for block panel or 1W panel,4-8 digits can be selected. from1 to 4-8 digits is allowe to enter.

 
 

Pincode

[Meet panel] PINCODE webserver

It allows you to change the INSTALLER PIN code, to access the installation configuration parameters through a web browser.

Enter the current code, the new pin and confirm it.  
The new password can have alphanumeric characters and has no limit on its length.

Finally, select SAVE.

NOTE:

Make a note of the new PIN at your convenience. If you lose or forget your PIN, you should contact FERMAX's Technical Department to receive instructions regarding its recovery. All settings programmed into the panel will be lost after recovery.

 
 

WeChat QR

[Meet panel M+K] Wechat QR webserver

This function is not available in this version of Firmware V 03.70. It is recommended to deactivate it in the web server so that the icon does not appear in the lower part of the screen of the KIN.

 
 

Management

[Meet panel] Management webserver

Use this functionality to import, export configuration file, reboot remotely  the panel, return it to factory settings, or log out webserver

CONFIGURATION FILE: Allow installers to save a backup of its configuration via export button, later apply that previously exported file via import button to the same or a different KIN panel with same version.

  • The exported configuration file do not include imported picture, the language file ,directory file and sip call file.
  • Press import button, the pop will appear.
  • Press SKIP, the general settings from be imported configuration file, if the general settings is different with imported configuration file, modify general settings and press OK.

[Meet panel M+K] Management restore factory setting webserver

RESTORE FACTORY SETTINGS: The panel will automatically turn off and start up with the factory settings. We refer below the essential default parameters for your reference.

GENERAL

  • BLOCK: 1
  • DEVICE: 1 
  • LANGUAGE: ENGLISH
  • VIDEO RESOLUTION: 640 x 480
  • INSTALLER PASSWORD:123456 

NETWORK

  • IP: 10.1.0.1
  • MASK: 255.0.0.0
  • GATEWAY: 10.254.0.1
  • DNS: 8.8.8.8
  • SOFTWARE IP: 10.0.0.200

Any other parameters (sip, IP cameras, concierges, etc.) that have been configured will also be lost.

[Meet panel] Management reboot + log out webserver

REBOOT DEVICE: The panel will automatically turn off and start up keeping all the programming parameters.      
When resetting, the device will lose connection with the PC. Refresh the website after about 60 seconds to resume the connection.

LOG OUT: Press OK and log out webserver, appear interface of log in.

 
 

Operation

The screen of the MILO PANEL is interactive, so its performance depends on the call process or selected funtion. 

When someone stands in front of the panel or press button, a standby interface is shown. This standby interface loop playback, depending on the programming settings. 

It is also possible to select one of the available function icons via shortcut or menu. These icons have to be enabled by the installer.

See WEB BROWSER PROGRAMMING section for further details.

Numerical Keypad

Apartments can be called only with numbers.

To call an apartment, dial apartment number and press the bell button. 

It is also possible to enter shortcut button or access menu and use the available icon functions (access code, face recognition, etc.), enter AA to enter QR CODE and face recognition, enter A0 to enter access code, enter A7 to enter guest code, enter A8 to directory.

On screen information 

It is possible to get basic information on the equipment configuration through the screen.

 

 

Dial 9999,  followed by Bell button.

 

The screen will display information about panel settings:

  • Firmware version
  • General settings
  • MQTT ID
  • MAC
  • IP address

.     Standby

If the keypad is not be used and nobody is in front of the panel, the display turns off after 1 minutes for energy saving.

Icon functions

Depending on the programming and capabilities of the installation, some icon functions will be available in the menu. 

Up to 4 icons will appear on the screen. If there were more than 4 functions available, use the arrow button to make visible the hidden one.                           
The utility of each icon is explained below. Select the corresponding icon and press B button to use the associated function.

Face recognition icon

Users can be identified by means of facial recognition. 

Press arrow button and access to menu, select this icon via arrow button, then press “B”, Alternatively AA when the panel is standby, the face recognition interface will appear. Users should stay for a few seconds in front of the panel.         
If the user´s face has been programmed and the system recognises him, the door will open.

NOTE:
Face recognition requires previous programming by means of the FERMAX MEET MANAGEMENT Software. 

 
 

QR code icon

This option allows users to open the door by means of scaning a QR code that has been provided to him, for example to get access during a certain day.  

微笑的女人

描述已自动生成

The panel shall have installed a GUEST CODE MODULE Ref.1494, as explained in the INSTALLATION section. A third-party Access Control System is required. 

 
 

Directory icon

It allows to use a directory for selecting and calling an apartment searching the owner´s name. Press arrow button and access to menu, select this icon via arrow button, then press “B”, Alternatively A8 when the panel is standby, the agenda interface will appear.

Select apartment via arrow button, then press bell button.

It is possible to search a name, press the number which contain the initial character and it will filter the names which their first character matches.

A programming is requiered.  See WEB BROWSER PROGRAMMING section for further details.

 
 

Guest code icon

This option allows users to open the door by means of entering a PIN code that has been provided to him, for example to get access during a certain day.     

Press arrow button and access to menu, select this icon via arrow button, then press “B”, or press “A7” when the panel is standby, the Guest code interface will appear, users shall enter the valid guest code followed by “B” to open the door.

If a wrong code is entered the panel will show an INVALID CODE message.

The panel shall have installed a GUEST CODE MODULE Ref.1494, as explained in the INSTALLATION section. A third-party Acces Control System is required. 

 
 

Access pin icon

This option allows users to open the door by means of entering an access code. Length of access code could be between 4 to 6 digits.

The panel admits up to 8 different access codes, that must be programmed by the installer.  

The users can enter pin via different mode

Enter directly pin when the panel is standby , then followed by “B” button, It is not necessary to enter ‘A0’.

Press arrow button and access to menu, select this icon via arrow button, then press “B”,  press “A0” when the panel is standby, the Access code interface will appear, Users shall enter the valid Access code followed by “B” button to open the door.

If a wrong code is entered the panel will show an INVALID CODE message.

See WEB BROWSER PROGRAMMING section for further details.

DIRECT ACCESS TO FUNCTION

Only one function enable for agenda, guest code ,Qr code ,pin code , face recognition or wechat QR,

Press arrow and direct access UI of function .

图形用户界面, 文本, 应用程序

AI 生成的内容可能不正确。   图形用户界面, 文本, 应用程序, 聊天或短信

AI 生成的内容可能不正确。    

图形用户界面, 文本, 应用程序

AI 生成的内容可能不正确。  图形用户界面, 文本, 应用程序, 聊天或短信

AI 生成的内容可能不正确。    图形用户界面, 文本, 应用程序, 聊天或短信

AI 生成的内容可能不正确。

 
 
 
 

Mode function

The panel call concierge with NIGHT mode or the block panel call general concierge be enabled ONLY RECEIVED G.E. PANEL CALLS, the panel show Concierge out of service.

The concierge with DAY mode, the panel call apartment and will transfer to concierge at once.

The concierge enables Monitoring, the panel call apartment, calling countdown time from 15s, the monitor no answer or no release lock during 15s will transfer to concierge. 

The concierge disables Monitoring, the panel call apartment, calling countdown time from 30s, the calling will not transfer to concierge.

 
 

Transfer function

The panel will show PLEASE WAIT if the concierge access to transfer interface.

The panel will call apartment if the concierge via transfer directly.

The panel will establish conversation with monitor after the concierge conversation with monitor and agree to transfer, otherwise the concierge will automatically resume the conversation with the caller.

 
 

Installation and diagrams

Flush box installation

 
 

Installation guide diagram

1. Flush box install

2.  Base flush box depth adjustment hook.

3. The upper part of the panel is stuck in, then move the panel to the flush box.

4. Move the slider of the panel and fix the two screws. When installing, pay attention to the reservation of the 2 cm space around the door to move the slide cover.

 
 

Connections

[Meet panel M+K] Connectors 

The panel is connected to the installation by means of connectors: Ethernet for LAN connection and MOLEX type connectors for other connections (power supply, RS-485, etc.). A bag containing the corresponding female connectors with their cables comes with the panel.

POWER INPUT: 12 Vdc power supply for the cases where no LAN PoE is available.

OUTPUT: Electric lock control relay output.

  • NC: Normally closed contact
  • NO: Normally opened contact
  • C: Common
  • NOTE: NC & C contacts are internally duplicated 

EX PROXIMITY (external proximity reader)

  • (WD0-WD1) Wiegand input/output
  • (+5V, -) 5 Vdc auxiliar output 

Exit Button /Fire / Door Sensor. See NOTE.

  • (EXIT, -) Connections for indoor button 
  • (F, -) Input for fire alarm & block doors unlock contacts
  • (DS, -) Connection for door opened sensor

RS485

  • Output for Ref. 1491/Ref. 9545 MEET LIFT Control Gateway, Ref. 1494 Guest code or Ref. 1490 External Relay (*)
    (*) Ref. 1490 works as an auxiliar relay in parallel with the panel´s relay.

RJ 45 Network

  • RJ-45 LAN or LAN PoE connection

NOTE:
EXIT, FIRE and DS require installer programming. See WEB BROWSER PRORAMMING for further details.
EXIT button allows users to open the door from inside.
FIRE input in PANEL No 1 has to be connected to a fire output relay of a third-party fire alarm system. If a fire alarm is triggered, an alarm will sound in all the panels of the block, and all the doors will remain opened.
Installing a door open sensor in DS, an alarm sounds in the panel and concierge if the door remains opened during a programmed period, or the door has been forced as well.
The panel has an internal tamper button. If the panel is separated from the wall, an alarm is triggered in the panel, concierge (if exists).
 

 
 

Basic diagrams

[Meet panel M+K] Basic diagrams

Basic diagram using PoE Switch.

Use a power supply adapted to the electric lock voltage & current.

Basic diagram using no PoE switch.

Supply the panel by means of a FERMAX Ref. 4813 (12 Vdc 2A) power supply.

Use a power supply adapted to the electric lock voltage & current. Do not power the panel and the electric lock from the same power supply.

 
 

Diagram installation of the 4 relay module ref.1491

[Meet panel M+K] DIAGRAM INSTALLATION OF THE 4 RELAY MODULE REF. 1491 

This module is neccessary if you want to use the function of activating from the monitors additional relays (up to 4), for example to activate additional doors or gates.

NOTE: 

The 1491 module need be connected to the PANEL No.1 in the block. 

 
 

Diagram installation of the guest module ref.1494

 
 

Diagram installation of the lift control system ref.9545

[Meet panel  M+K] DIAGRAM INSTALLATION OF THE LIFT CONTROL SYSTEM REF.9545

This installation has to be performed in the PANEL nº 1 of the corresponding block only.

 
 

Firmware updates

[MEET panel] Firmware updates

Sometimes it may be necessary or convenient to update a new firmware version because improvements or corrections have been incorporated into its operation. 

FERMAX's Technical Department periodically informs (through Communications, Technical Bulletins, etc.) about the release of a new firmware update, as well as the improvements incorporated.                           
Contact the FERMAX Technical Department if you wish to receive the corresponding update file.

The firmware update is performed via the FERMAX MEET System Upgrading Tool V01.00.exe. The procedure for updating the firmware with the corresponding update file is as follows:

  1. Start the FERMAX MEET System Upgrading Tool v1.00. exe.
  2. Click on “…” button and browse the PC to find the corresponding .IMG update file.         
    Up to 3 .IMG files can be selected at the same time (for the case of the update has more than unique .IMG file). 
  3. Indicate the IP Range of the panels. 
  4. Click on “Start”.

The new firmware will be installed, and the panel will restart automatically.

 

 

 

 

 

 

milo nautical

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Video Door Entry Systems
  • Monitors
  • Telephones
  • Outdoor Panels
  • Kits
  • Systems
  • Door Lock Release
  • Access Control
  • Memokey
  • Proximity
  • Inkey
  • Radio Frequency
  • Centralized AC-MAX
  • Technical Support
  • FAQs
  • Software
  • Manuals
  • Warranty
  • Customer Care
  • Tools
  • PROELITE
  • Global Projects
  • Skyliner
  • Cardholder Designs
  • Special Panels
  • Documentation
  • Technical Documentation
  • Corporate Identity Manual
  • Catalogues and Brochures
  • General Catalogue
  • About Fermax
  • History
  • Prizes
  • Projects
  • Work in Fermax
  • Cybersecurity
  • Fermax Network
  • Newsroom
  • Quality Policy
  • FERMAX WORLDWIDE
  • España
  • Internacional Español
  • International English
  • International Français
  • Portugal
  • United Kingdom
  • France
  • Belgium - Français
  • Belgium - Nederlands
  • Polska
  • Norsk
  • Svenska
  • Fermax logo
  • Fermax International
  • Privacy Policy
  • Cookies policy
  • Webmap
  • Ethics Channel
  • Tel: +34 96 317 80 11
  • export@fermax.com
Expand